Recovery of Airborne Aerobic Bacteria and Fungi from Hospitals of Varying Bed Strength in a Tropical Setting

Authors

  • Suchithra Sudharsanam Sri Ramachandra Medical College and Research Institute, Sri Ramachandra University, Porur, Chennai, Tamil Nadu-600116.
  • Mohanbabu Ethiraj Sri Ramachandra Medical College and Research Institute, Sri Ramachandra University, Porur, Chennai, Tamil Nadu-600116.
  • Gurusamy Thangavel Sri Ramachandra Medical College and Research Institute, Sri Ramachandra University, Porur, Chennai, Tamil Nadu-600116.
  • Sandhya Swaminathan National Environmental Engineering Research Institute, CSIR-complex, Taramani, Chennai, Tamil Nadu, 600113-India.
  • Ravi Annamalai Sri Ramachandra Medical College and Research Institute, Sri Ramachandra University, Porur, Chennai, Tamil Nadu-600116.
  • Padma Srikanth Sri Ramachandra Medical College and Research Institute, Sri Ramachandra University, Porur, Chennai, Tamil Nadu-600116.

Abstract

Objectives: Study was undertaken in Chennai, India to 1) determine the impact of hospital bed strength and sampling location on recovery of airborne microorganisms; and 2) characterize microorganisms (aerobic bacteria and fungi) isolated.

Methods: Indoor air samples (duplicates) were collected from intensive care units (ICUs), operating rooms (ORs) and wards of six (two < 10 bed (group I), three ~100 bed (group II) and one > 100 bed (group III)) hospitals over one-year period using exposed-plates for time periods of 30 minutes. Sampling media included 5% Sheep Blood agar and MacConkey agar for bacteria and Rose Bengal agar for fungi.

Result: A total of 2 ORs and 2 wards from group I, 3 ICUs, 3 ORs and 3 wards from group II, and 4 ICUs, 3 ORs and 8 wards from group III hospitals were sampled. Airborne microbial loads ranged between 46-59 CFU/ plate in ICUs, 17 -26 CFU/ plate in ORs and 63-100 CFU/ plate in wards. Airborne microbial loads varied significantly with sampling locations (p < 0.001); variation in airborne microbial loads with hospital bed strength was statistically insignificant (Kruskal-Wallis test). Coagulase-negative Staphylococci and Pseudomonas sp., and Aspergillus sp. were the predominant bacteria and fungi recovered respectively from air of all the hospitals under study.

Conclusion: Appropriate location-specific measures such as regulated temperature-humidity levels and air exchanges need to be implemented to contain their spread.

How to cite this article:
Sudharsanam S, Ethiraj M, Thangavel G et al. Recovery of Airborne Aerobic Bacteria and Fungi from Hospitals of Varying Bed Strength in a Tropical Setting. Int J Adv Res MicroBiol Immunol 2019; 1(1): 12-18.

References

Jaffal AA, Nsanze H, Bener A et al. Hospital airborne microbial pollution in a desert country. Environment International 1997; 23: 167-72.

Sarca S, Asan A, Otkun MT et al. Monitoring Indoor Airborne Fungi and Bacteria in the Different Areas of Trakya University Hospital, Edirne, Turkey. Indoor Built Environ 2002; 11: 285-92.

Obbard JP, Fang LM. Airborne concentrations of bacteria in a hospital environment in Singapore. Water Air Soil

Pollut 2003; 144: 333-41.

Sudharsanam S, Srikanth P, Sheela M et al. Study of Indoor Air Quality in Hospitals in South Chennai, India-Microbial Profile. Indoor Built Environ 2008; 17: 435-41.

Ekhaise FO, Ighosewe OU, Ajakpovi OD. Hospital Indoor Airborne Microflora in Private and Government Owned

Hospitals in Benin City, Nigeria. World J Med Sci 2008; 3: 19-23.

Qudiesat K, Abu-Elteen K, Elkarmi A et al. Assessment of airborne pathogens in healthcare settings. Afr J Microbiol Res 2009; 3: 66-76.

Stetzenbach LD. Introduction to Aerobiology. In: Manual of Environmental Microbiology. 2nd ed. Hurst CJ, Crawford RL, Knudsen G et al. (Ed.). Washington DC: ASM Press, 2002: 801-13.

Gruendemann BJ, Mangum SS. Surgical environments and traffic. In: Infection Prevention in Surgical settings.

Philadelphia: Elsevier Publications, 2001: 22-23.

Sudharsanam S, Annamalai R, Ethiraj M et al. Factors influencing the microbial loads in indoor bioaerosols of a closed system of a healthcare facility in a tropical setting. Indian J Aerobiol 2011; 24(1): 7-11.

Augustowska M, Dutkiewicz J. Variability of airborne microflora in a hospital ward within a period of one year. Ann Agric Environ Med 2006; 13: 99-106.

Sudharsanam S, Swaminathan S, Ramalingam A et al. Characterisation of indoor bioaerosols from a hospital ward in a tropical setting. Afr Health Sci 2012; 12: 217-25.

Nasir ZA, Colbeck I. Assessment of bacterial and fungal aerosol in different residential settings. Water Air Soil

Pollut 2010; 211: 367-77.

Macher JM, Streifel AJ, Vesley D. Problem buildings, Laboratories and Hospitals. In: Cox CS, Wathes CM (Eds.). Bioaerosols handbook. New York: Lewis Publishers, 1995: 505-30.

Sudharsanam S, Srikanth P, Krishnamurthy S et al. Microorganisms in bioaerosols in indoor air of hospital and non-hospital Settings. Sri Ramachandra Journal of Medicine 2009; 2: 52.

Collee JG, Fraser AG, Marmion BP et al. Mackie and McCartney Practical Medical Microbiology. 14th Edn. New York: Churchill Livingstone Publications, 1999: 135-50.

Baron EJ, Peterson LR, Finegold SM. Bailey and Scott’s Diagnostic Microbiology. 9th Edn. St Louis: Mosby-Year

Book, 1994: 321-52, 362-428, 457-65.

Barnett HL, Hunter BB. Illustrated Genera of Imperfect Fungi. 4th Edn. St Paul: APS Press, 1999.

Center for Disease Control and Prevention. Guidelines for Environmental Infection Control in Health-Care

Facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). MMWR 2003; 52(RR-10): 1-42.

Downloads

Published

2019-12-20